Convectronics Heaters • Sensors • Controls
Home Products Technical Information Catalog Contact us Customer Forms About us
 
 
Electric Air Heaters
Tubular Heater Products
Temperature Sensors
Temperature Sensors
 
Catalog
Download Catalog
 
Home > Products > Temperature Sensors > TC Types and Applications > Standard Applications Product Configurator
When you need a heat source, Convectronics’ products are designed to meet and exceed all expectations!
 

Temperature Sensors
Standard Applications
Product Configurator

   
  Bare Wire Thermocouples
   
 
   
   
   
 
Wire AWG ANSI Type Part Number
8 J
K
T
E
(R/S)*
TAZA-12.0E
14 TAZB-12.0E
16 TAZC-12.0E
20 TAZD-12.0E
24 TAZE-12.0E
 
HOW TO ORDER:
 
ANSI Type
Thermocouple Style
Wire AWG
Length (Inches)
Junction Type
       
     
EXAMPLE:
To order a 20” long - 8 AWG wire - ANSI type “J” element, the part number is:
 
ANSI Type
Thermocouple Style
Wire AWG
Length (Inches)
Junction Type
  * Standard gauge wire to be used on noble metal thermocouples (R/S): 24 AWG.
* Standard ceramic insulators for noble metal thermocouples is high purity alumina oxide.
* Other types of ceramic insulators are available - consult factory.
* Multiple junction units available - consult factory.
   
   
   
  Insulated Wire Thermocouples
   
 
       
       
 
Ceramic
Bead DIA.
Wire
AWG
ANSI
Type
Part Number
1/8 24 J
K
T
E
(R/S)*
TAW2-12.0E
3/16 20 TAW3-12.0E
1/4 14 TAW4-12.0E
3/8 8 TAW6-12.0E
HOW TO ORDER:
 
ANSI Type
Thermocouple Style
Diameter Ceramic Bead
Length (Inches)
Junction Type
   
     
EXAMPLE:
To order an 18” long - 20 AWG wire - ANSI type “K” element, the part number is:
 
ANSI Type
Thermocouple Style
Diameter Ceramic Bead
Length (Inches)
Junction Type
   
  > To Top    
       
 
       
 
Spade Lug Size ANSI Type Part Number
No.10*
Spade Lug
Standard
J
K
T
E
TAQ3-24.0
 
HOW TO ORDER:
 
ANSI Type
Thermocouple Style
Spade Lug *(#10 Standard)
Flexible Lead Length (Inches)
     
EXAMPLE:
To order a Spade Lug Thermocouple with standard #10 spade lug, ANSI Type “K”, the part number is:
 
ANSI Type
Thermocouple Style
Spade Lug *(#10 Standard)
Flexible Lead Length (Inches)
       
       
 
       
 
Wire AWG ANSI Type Part Number
20 J
K
T
E
TAS-24.0EA
24 TAS-24.0EB
30 TAS-24.0EC
36

TAS-24.0ED

 
HOW TO ORDER:
 
ANSI Type
Thermocouple Style
Flexible Lead Length (Inches)
Gauge Wire
     
EXAMPLE:
To order an Exposed Bead Welded Thermocouple ANSI type “K”, 24” long with 20 gauge wire, the part number is:
 
ANSI Type
Thermocouple Style
Flexible Lead Length (Inches)
Gauge Wire
  * When ordering, specify part number and quantity; if flexible lead length is other than 24”,
specify accordingly and adjust base price.
* All types of Thermocouple wire insulations and gauge sizes are available - consult factory.
* All types of metal overbraid or flexible armor are available - consult factory.
* Other styles of termination are available.
   
  > To Top
   
  Pipe Probe Thermocouples
   
 
       
       
     
 
Hose Clamp
Size
ANSI
Type
Junction
Type
Part Number
1-12" J
K
T
E
Grounded TBC-72.0G
 
HOW TO ORDER:
 
ANSI Type
Thermocouple Style
Hose Clamp Size (Inches)
Length of Leads(Inches)
Junction Type: Grounded
 
   
     
  CONVECTRONICS’ Pipe Probe is designed for use in applications where Heat Pipes, Water, Band Heaters or Round products require surface temperature measurements. Having an adjustable Stainless Steel Hose Clamp allows this unit to be used extensively over a large range of sizes.  
       
     
       
  Sabre Style Thermocouples
       
 
       
       
 
Sheath
Size Dia.
Sheath
Material
ANSI
Type
Junction
Type
Part Number
1/8" 316
ST.
STEEL
J
K
T
E
Grounded TBA2-06.0G
3/16" TBB3-06.0G
 
HOW TO ORDER:
 
ANSI Type
Thermocouple Style
Sheath Diameter
Sheath Length (Inches)
Junction Type: Grounded
 
     
  Convectronics’ Sabre Thermocouple has been specifically designed for use in the food industries. The all-stainless steel construction with teflon insulated extension leads is completely autoclavable. Having a pointed tip this assembly lends itself to applications where semi-frozen, hard or raw foodstuffs must be penetrated for exact temperature readouts during preparation stages.  
     